Product Features

  • Battery is of the valve-regulated lead-acid (VRLA) type
  • Maintenance-free; with AGM (Absorbent Glass Mat) technology, gas recombination efficiency can reach up to 99%
  • Construction uses pure lead with proprietary elements
  • Developed for high-rate UPS and float standby power applications
  • Manufactured in accordance with IEC 60896-21/22:2004; UL1989 recognition (MH14533) has also been obtained

Application Scenarios

  • UPS long-duration backup — data centers
  • Long-duration standby power — large computer rooms
  • Long-duration discharge backup — industrial UPS
  • Long-duration backup — financial systems
  • Long-duration standby power — communication hubs
  • Long-duration UPS — medical centers

Product parameters

  • Model:XPL2200
  • Voltage:12 Vdc
  • Nominal Capacity:2200W @5min-rate
  • Watts per Cell:563.00 (30-Sec 1.67 VPC @ 25°C)
  • Watts per Cell:366.17 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:201.50 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:18.30 A
  • Max. Discharge Current:500 A
  • Short Circuit Current:1344 A
  • Internal Resistance:5.60 mΩ
  • Terminal Type:I2 thread lead alloy terminal to accept M6 bolt
  • Terminal Torque:51.7±10.3 Kgf·cm / 44.9±9.0 Lbf·in / 5.1±1.0 N·m
  • Container Material:PP (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:16.65 / 36.70 kg / lb.
  • Length (L):228.0±2.5 / 8.98±0.10 mm / in
  • Width (W):138.4±1.5 / 5.45±0.06 mm / in
  • Height (H):206.3±2.5 / 8.12±0.10 mm / in
  • Design Life:Up to 10 years in standby service at 25°C; Eurobat (20°C): >12 years, Very Long Life
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C

Product details

The CSB XPL2200 in the XPL series is a 12V top-terminal valve-regulated sealed lead-acid battery that combines pure lead and AGM technology in its construction. For long-duration standby applications requiring high-capacity monobloc units, this series meets the need; data center uninterruptible power supplies are its official application direction. At 25°C, nominal capacity is 2200W @5min-rate. Cell power (W/cell) at 1.67 VPC is: 563.00 W/cell at 30 seconds, 366.17 W/cell at 5 minutes, and 201.50 W/cell at 15 minutes. Electrically, internal resistance is 5.60 mΩ and short-circuit current is 1344 A; maximum discharge current is 500 A, and maximum charge current is 18.30 A. At 25°C, float voltage must be maintained at 13.5 to 13.8 Vdc/battery, and equalization voltage at 14.4 to 15.0 Vdc/battery. Terminals are I2 threaded lead alloy and can accept M6 bolts, with tightening torque of 51.7±10.3 Kgf∙cm, 44.9±9.0 Lbf∙in, or 5.1±1.0 N∙m. Length, width, and height are 228.0±2.5 mm, 138.4±1.5 mm, and 206.3±2.5 mm respectively, with a total weight of 16.65 kg (36.70 lb). PP (UL 94-HB) is used for the case; if flame retardant (94-V0) is required, it can also be supplied on request. Design life is up to 10 years under 25°C float standby service, and the Eurobat (20°C) rating exceeds 12 years, providing ultra-long life. For temperature specifications, 25°C is the nominal value; discharge range is -15°C to 50°C; charge and storage range is -15°C to 40°C. For self-discharge, after 90 days at 25°C, self-discharge is less than 10%; maximum storage is 6 months, or up to 10 months with equalization charging. Fully charge before first use; if storage temperature exceeds 25°C, charge earlier. The valve-regulated sealed lead-acid design plus AGM technology forms the foundation of the XPL2200, with gas recombination efficiency up to 99% and no maintenance required. The pure lead construction and proprietary element design target high-rate UPS and float standby power. Manufacturing follows IEC 60896-21/22:2004, and UL1989 recognition (MH14533) has also been obtained.