Valve Regulated Sealed Lead Acid Battery 6V/34W (CSB HRL634W)
For high-rate float standby power applications such as data center UPS, the CSB HRL634W in the HRL series uses AGM technology and pure lead construction, with a 6V valve regulated sealed lead acid design and a nominal capacity of 34W at the 15-minute rate.
Taobao store
WeChat procurement
Product Features
- VRLA (valve-regulated lead-acid) battery
- Maintenance-free, using AGM (Absorbent Glass Mat) technology, with gas recombination efficiency up to 99%
- Pure lead construction with proprietary elements
- Specifically designed for high-rate UPS and float standby power applications
- Manufactured in accordance with IEC 61056-1/2:2012 and UL1989 recognized (MH14533)
Application Scenarios
- UPS backup power, suitable for large data centers
- High-voltage DC backup power, serving cloud computing centers
- Uninterruptible power supply, for financial trading systems
- UPS emergency backup, for communication hubs
- High-power UPS backup, applied in industrial automation
- UPS backup, paired with rail transit signaling systems
Product parameters
- Model:HRL634W
- Voltage:6 Vdc
- Nominal Capacity:34W @15min-rate
- Watts per Cell:36.33 (5-Min 1.67 VPC @ 25°)
- Watts per Cell:18.17 (15-Min 1.67 VPC @ 25°)
- Max. Charge Current:3.40 A
- Max. Discharge Current:130 A
- Short Circuit Current:380 A
- Internal Resistance:8.30 mΩ
- Terminal Type:F2 terminal (Faston Tab 250)
- Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
- Weight:1.32 / 2.91 kg / lb.
- Length (L):150.9±2.0 / 5.94±0.08 mm / in
- Width (W):34.0±1.0 / 1.34±0.04 mm / in
- Height (H):98.6±1.0 / 3.88±0.04 mm / in
- Design Life:Up to 8 years in standby service at 25°C; Eurobat (20°C): 10-12 years, Standard Commercial
- Float Charging Voltage:6.75 - 6.90 Vdc/battery
- Equalizing Charging Voltage:7.20 - 7.50 Vdc/battery
- Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C
Product details
HRL634W is a member of the HRL series, which covers 6V and 12V top terminal VRLA-AGM batteries and is officially designated for data center uninterruptible power supplies. The series is positioned for long-life, high-rate UPS pure lead batteries, targeting high-power data centers and UPS loads. Its design combines a valve regulated sealed lead acid structure with absorbed glass mat technology, achieving gas recombination efficiency of up to 99% and maintenance-free operation; it is manufactured with pure lead construction and a proprietary element formula for use in high-rate UPS float standby power applications.
In terms of appearance and construction, the HRL634W is equipped with F2 terminals, also known as Faston Tab 250. The case uses ABS (UL 94-HB), and a flame-retardant 94-V0 version can also be provided when required. Weight is 1.32 kg (2.91 lb). Dimensions are: length 150.9±2.0 mm (5.94±0.08 in), width 34.0±1.0 mm (1.34±0.04 in), height 98.6±1.0 mm (3.88±0.04 in).
Electrically, the battery has a rated voltage of 6 Vdc; at 1.67 VPC and 25°C, the nominal capacity at the 15-minute rate is 34W. Among the per-cell power data, the 30-second, 1.67 VPC, 25°C condition is not listed in the documentation; at 5 minutes, 1.67 VPC, 25°C it is 36.33 W/cell; at 15 minutes, 1.67 VPC, 25°C it is 18.17 W/cell. Current and internal resistance specifications are as follows: maximum charge current 3.40 A, maximum discharge current 130 A, short-circuit current 380 A, internal resistance 8.30 mΩ. At 25°C, the float voltage range is 6.75 to 6.90 Vdc/battery, and the equalization voltage range is 7.20 to 7.50 Vdc/battery.
For life and temperature, the design life under 25°C float standby is up to 8 years; the Eurobat (20°C) standard commercial life is 10 to 12 years. Nominal operating temperature is 25°C (77°F). Discharge is permitted from -15°C to 50°C (5°F to 122°F), and charging and storage are permitted from -15°C to 40°C (5°F to 104°F). For self-discharge, it is less than 10% after 90 days; storage at 25°C (77°F) can last up to 6 months. It must be fully charged before re-use, and if the storage temperature exceeds 25°C (77°F), earlier charging is required.
This product is manufactured in accordance with IEC 61056-1/2:2012 and has UL1989 recognition (MH14533). Based on the above characteristics, the HRL634W is suitable for scenarios such as data center UPS that require both high-rate discharge and float standby, and its design and performance can be demonstrated at 25°C.