For applications such as data center UPS systems that require high-rate discharge, the CSB HR1218W uses a pure lead and AGM design and is a 12V valve-regulated sealed lead-acid battery. The battery delivers 38.1 W/cell at the 5-minute rate and 17.8 W/cell at the 15-minute rate; under float charging, its design life can reach 5 years.
Taobao store
WeChat procurement
Product Features
- Valve-regulated lead-acid battery, i.e. VRLA type
- Maintenance-free; uses AGM (absorbent glass mat) technology, with gas recombination efficiency up to 99%
- Constructed with a pure lead structure combined with proprietary elements
- Specially developed for high-rate UPS and float-charge standby power applications
- Manufactured in accordance with IEC 61056-1/2:2012 and UL1989 recognized (MH14533)
Application Scenarios
- UPS backup for small and medium-sized data centers
- Uninterruptible power supply for server racks
- Emergency power protection for network equipment rooms
- UPS backup for medical imaging equipment
- Fast discharge for industrial control UPS
- Backup power for precision instruments in laboratories
Product parameters
- Model:HR1218W
- Voltage:12 Vdc
- Nominal Capacity:18W @15min-rate
- Watts per Cell:38.1 (5-Min 1.67 VPC @ 25°)
- Watts per Cell:17.8 (15-Min 1.67 VPC @ 25°)
- Max. Charge Current:1.80 A
- Max. Discharge Current:130 A
- Internal Resistance:28.5 mΩ
- Terminal Type:F2 terminal (Faston Tab 250)
- Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
- Weight:1.53 / 3.37 kg / lb.
- Length (L):150.9±2.0 / 5.94±0.08 mm / in
- Width (W):51.0±1.0 / 2.01±0.04 mm / in
- Height (H):98.6±1.0 / 3.88±0.04 mm / in
- Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
- Float Charging Voltage:13.5 - 13.8 Vdc/battery
- Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
- Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C
Product details
CSB officially positions the HR1218W for small-output UPS and fast-discharge backup power applications, and it belongs to the HR series of high-rate discharge pure lead batteries. In data center uninterruptible power supply systems, this model can provide short-duration high-rate backup power to critical loads; thanks to its maintenance-free design and compact size, it is easy to integrate into UPS cabinets with limited space.
Capacity and power are rated as follows: at 1.67 VPC @25°C, nominal capacity is expressed as 18W at the 15-minute rate; the 5-minute rate power is 38.1 W/cell, and the 15-minute rate power is 17.8 W/cell. These characteristics make it suitable for backup power applications requiring short-duration high-power output.
Mechanical dimensions: length 150.9±2.0 mm, width 51.0±1.0 mm, height 98.6±1.0 mm, weight approximately 1.53 kg. Operating temperature ranges include: nominal 25°C; discharge -15°C to 50°C; charge and storage -15°C to 40°C. Design life is up to 5 years under float charging at 25°C; under the Eurobat standard, 3 to 5 years at 20°C.
Electrical parameters: nominal voltage 12 Vdc, maximum charge current 1.80 A, maximum discharge current 130 A, internal resistance 28.5 mΩ. At 25°C, float voltage is 13.5 to 13.8 Vdc/battery, and equalization voltage is 14.4 to 15.0 Vdc/battery. Terminal type is F2-Faston Tab250. When stored for 90 days at 25°C, the self-discharge rate is below 10%, and it can be stored for up to 6 months; fully charge before use, and if storage temperature is above 25°C, charge earlier.
In terms of type, the HR1218W is a 12V valve-regulated sealed lead-acid battery, using absorbent glass mat technology, with gas recombination efficiency up to 99%, and a maintenance-free design. The positive and negative plates use pure lead construction and a proprietary formulation, which helps high-rate discharge performance. The case material is ABS, meets the UL 94-HB flame retardancy rating, and a 94-V0 flame-retardant version can also be provided on request. The battery complies with IEC 61056-1/2:2012 and is recognized under UL1989.
When using the HR1218W, follow the specified charging voltage and temperature ranges to ensure performance and service life.