12V Front Terminal Valve-Regulated Sealed Lead-Acid Battery CSB XHRL12600WFTFR (CSB)
For high-rate float standby applications such as data center UPS, CSB offers the XHRL12600WFTFR. This model is a 12V front terminal valve-regulated sealed lead-acid battery in the XHRL-FT series, using AGM technology, with a nominal capacity of 600W @ 15min-rate.
Taobao store
WeChat procurement
Product Features
- VRLA valve-regulated sealed lead-acid battery
- Maintenance-free; with AGM absorbent glass mat technology, gas recombination efficiency up to 99%
- Pure lead construction with proprietary elements
- Designed for high-rate UPS and float standby power applications
- Manufactured to IEC 60896-21/22:2004 and UL1989 recognized (MH14533)
Application Scenarios
- UPS backup for data center front-terminal applications
- Backup power for telecom equipment rooms, with high-rate discharge capability
- Fast-discharge battery, compatible with rack-mounted UPS
- Emergency power supply for edge data centers
- Backup power retrofit for front-access wiring cabinets
- UPS backup, suitable for industrial control cabinets
Product parameters
- Model:XHRL12600WFTFR
- Voltage:12 Vdc
- Nominal Capacity:600W @ 15min-rate
- Watts per Cell:1766.00 (30-Sec 1.67 VPC @ 25°C)
- Watts per Cell:1144.17 (5-Min 1.67 VPC @ 25°)
- Watts per Cell:642.50 (15-Min 1.67 VPC @ 25°)
- Max. Charge Current:60.00 A
- Max. Discharge Current:1550 (5sec)
- Short Circuit Current:4132 A
- Internal Resistance:2.01 mΩ
- Terminal Type:I2 thread lead alloy terminal to accept M6 bolt
- Terminal Torque:51.7±10.3 Kgf·cm / 44.9±9.0 Lbf·in / 5.1±1.0 N·m
- Container Material:PP (UL 94-HB) standard, flame-retardant (94-V0) available upon request
- Weight:49.70 / 109.57 kg / lb.
- Length (L):558.0±2.5 / 21.97±0.10 mm / in
- Width (W):126.0±1.5 / 4.96±0.06 mm / in
- Height (H):255.0±2.5 / 10.04±0.10 mm / in
- Design Life:Up to 10 years in standby service at 25°C; Eurobat (20°C): 12+ years, Very Long Life
- Float Charging Voltage:13.5 - 13.8 Vdc/battery
- Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
- Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C
Product details
For high-rate discharge float standby systems such as data center UPS, the CSB XHRL12600WFTFR is a 12V front terminal valve-regulated sealed lead-acid battery in the XHRL-FT series. Based on the XHRL platform, the series features a front terminal design that makes front-of-cabinet wiring and maintenance more convenient. The battery uses AGM absorbed glass mat technology, with a gas recombination efficiency of up to 99%. It is a maintenance-free design and is manufactured with a pure lead structure combined with proprietary elements.
Dimensions and terminals: The battery measures 558.0±2.5 mm long, 126.0±1.5 mm wide, and 255.0±2.5 mm high, and weighs 49.70 kg. The terminal is an I2 thread lead alloy terminal and accepts M6 bolts; terminal torque is 51.7±10.3 Kgf∙cm, 44.9±9.0 Lbf∙in, or 5.1±1.0 N∙m. The case material is PP (UL 94-HB); a flame-retardant 94-V0 version is available on request.
Charging, temperature, and storage conditions: At 25°C, the float voltage is 13.5 to 13.8 Vdc/battery, and the equalization voltage is 14.4 to 15.0 Vdc/battery. The nominal operating temperature is 25°C, the discharge range is -15°C to 50°C, and the charging and storage range is -15°C to 40°C. Self-discharge is below 10% after 90 days at 25°C. The battery can be stored for up to 6 months, or up to 10 months with equalizing charge, and must be fully charged before use; if the storage temperature is above 25°C, charge it earlier.
Power and electrical parameters: Nominal capacity is 600W @ 15min-rate at 10.02V per PCS, 25°C. Cell power is 1766.00 W/cell at 30 seconds, 1.67 VPC, 25°C; 1144.17 W/cell at 5 minutes, 1.67 VPC, 25°C; and 642.50 W/cell at 15 minutes, 1.67 VPC, 25°C. Maximum charge current is 60.00 A, maximum discharge current is 1550 (5sec), short-circuit current is 4132 A, and internal resistance is 2.01 mΩ.
Design life: Up to 10 years under float standby service at 25°C, and over 12 years ultra-long life under Eurobat (20°C) conditions. The product is manufactured in accordance with IEC 60896-21/22:2004 and is UL1989 Recognized (MH14533). With front terminals and high-rate power output, this model is suitable for float standby power systems such as data center UPS, and can be installed and maintained from the front of the cabinet.