12V 7.2Ah Valve-Regulated Sealed Lead-Acid Battery (CSB XTV1272WTFR)
The CSB XTV1272WTFR in the XTV-WT series is a 12V valve-regulated sealed lead-acid battery; it uses a pure lead plus AGM design, has a nominal capacity of 7.2Ah at the 20-hour rate and a float charge voltage of 13.5-13.8Vdc, and is intended for demanding environments such as wind power generation.
Taobao store
WeChat procurement
Product Features
- VRLA valve-regulated lead-acid battery
- Maintenance-free, using AGM absorbent glass mat separator technology, with gas recombination efficiency up to 99%
- Pure lead construction with proprietary elements
- Specifically designed for wind turbine applications
- Manufactured in accordance with IEC 61056-1/2:2012 and has received UL1989 recognition (MH14533)
Application Scenarios
- Backup power supply for pitch systems, serving wind turbines
- DC power supply inside the tower, for wind turbines
- Backup battery for yaw systems, used in wind power
- Backup power supply, compatible with offshore wind platforms
- Backup power supply for monitoring systems at wind farms
- Emergency power supply for wind turbines in harsh environments
Product parameters
- Model:XTV1272WTFR
- Voltage:12 Vdc
- Nominal Capacity:7.2Ah @ 20hr-rate
- Ah Capacity:6.72 (8-Hr 1.75 VPC @ 25°C)
- Ah Capacity:7.40 (20-Hr 1.75 VPC @ 25°C)
- Ah Capacity:6.56 (8-Hr 1.80 VPC @ 25°C)
- Max. Charge Current:2.16 A
- Max. Discharge Current:130 A
- Short Circuit Current:305 A
- Internal Resistance:20.40 mΩ
- Terminal Type:F2 terminal (Faston Tab 250)
- Container Material:Flame-retardant ABS
- Weight:2.57 / 5.66 kg / lb.
- Length (L):150.9±2.0 / 5.94±0.08 mm / in
- Width (W):64.8±1.0 / 2.55±0.04 mm / in
- Height (H):98.6±1.0 / 3.88±0.04 mm / in
- Design Life:Up to 12 years in standby service at 25°C; Eurobat (20°C): 10/12 years, Long Life
- Float Charging Voltage:13.5 - 13.8 Vdc/battery
- Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
- Operating Temperature:discharge/charge -20°C to 50°C; storage -15°C to 40°C
Product details
In renewable energy system energy storage and backup power applications, the CSB XTV1272WTFR can serve demanding environments such as wind power generation. It belongs to the XTV-WT series and is a 12V valve-regulated sealed lead-acid battery, featuring AGM absorbed glass mat technology, a maintenance-free design, and gas recombination efficiency of up to 99%. The series has a pure lead construction, and it is officially positioned as a VRLA-AGM pure lead battery for demanding environments such as wind power generation; its officially listed application area is renewable energy.
In terms of construction, the case is made of flame-retardant ABS material and meets the 94-V0 rating, and the terminals use the F2 Faston Tab 250 type. Dimensions are length 150.9±2.0mm, width 64.8±1.0mm, and height 98.6±1.0mm, with a weight of approximately 2.57kg. Under 25°C float charge conditions, the design life can reach 12 years; according to the Eurobat 20°C standard, it falls into the 10- to 12-year long-life category. The product is manufactured in accordance with IEC 61056-1/2:2012 and is UL1989 recognized (MH14533).
For capacity and current, at 25°C and 1.75VPC, the nominal capacity at the 20-hour rate is 7.2Ah, the measured capacity at the 20-hour rate is 7.40Ah, and the 8-hour rate capacity is 6.72Ah; at 1.80VPC, the 8-hour rate capacity is 6.56Ah. Maximum charge current is 2.16A, maximum discharge current is 130A, short-circuit current is 305A, and internal resistance is 20.40mΩ.
For charging and temperature, at 25°C the float charge voltage is 13.5 to 13.8Vdc, and the equalization charge voltage is 14.4 to 15.0Vdc. The operating temperature range for discharge and charge is -20°C to 50°C, the storage temperature is -15°C to 40°C, and the nominal operating temperature is 25°C. For self-discharge, after 90 days at 25°C the capacity loss is less than 10%, and it can be stored for up to 6 months; it should be fully charged before use, and if the storage temperature is above 25°C, charging is required sooner.
The maintenance-free and low self-discharge characteristics make it suitable for long-term deployment; specific installation and charging settings should be based on official technical documentation.